Conductor with a covering over it, not insulation around it. That distinction decides how a lot is reviewed, because there is no semiconducting screen and no metallic shield to test, and the covering hides the conductor it is meant to protect.

  • 15 kV to 35 kV
  • Tree wire and spacer
  • Covering damage
Coloured reels and timber pallets inside a green steel warehouse
Colored reels and timber pallets inside a green steel warehouse.

Sell your wire

Tell us what you have

Six details are enough to start. Photos can follow by text or email.

No fee and no obligation. Prefer to talk? 614-715-3047 or saleselectricalbuyers@gmail.com

01Overview

What this page covers

Covered conductor is bare aluminum or ACSR with a tough extruded covering, usually high molecular weight polyethylene or XLPE, in a wall from about 0.060 in. to 0.120 in. It is used where a line runs through trees and the utility wants to cut momentary outages without widening the right-of-way. Spacer cable takes the same conductor and hangs three covered conductors on spacers from a messenger.

Because there is no screen and no shield, the covering does not grade voltage the way cable insulation does. Water sits between the covering and the conductor, tracking happens along the surface, and a pinhole lets moisture wick down the strands. Those are the failure modes a buyer is looking for.

02Specification

What the reel and the covering tell us

Voltage classes
15 kV, 25 kV and 35 kV covered systems
Covering
HMWPE or XLPE, 0.060 in. to 0.120 in. wall, usually black
Conductor
ACSR, AAC or AAAC, 1/0 through 477 kcmil
Configurations
Single covered conductor on ties; three on spacers with a messenger
Messenger
AAAC or ACSR, with spacers at roughly 30 ft
Standards
Conductor to ASTM B232 and B231; covering to the utility specification
Reels
NEMA 48 in. to 72 in.; typically 2,500 to 5,000 ft
Condition
New surplus, removed from line, storm salvage, covering damaged

Look at the covering at the tie positions first. That is where abrasion starts, and where water gets in on a conductor that has been in service.

03Covered material we buy

Covered material we buy

01

Tree wire on ties

Single covered conductor on pin or suspension insulators through wooded right-of-way. The covering is abraded where the tie wire bit into it, and those points are where the aluminum underneath has been sitting wet.

02

Spacer cable systems

Three covered conductors held apart by spacers on a messenger, strung through tree canopy. The spacers, the messenger and the lashing or ties are part of the system and are reviewed with it, because a partial system is harder to re-use.

03

Covered conductor in the 35 kV class

Heavier covering on subtransmission-sized conductor, used where a line passes through a growth area. The covering is thicker and the conductor underneath is usually larger, which changes both the review and the weight.

04

Removed and salvaged lengths

Conductor taken down during a rebuild or after storm damage. Re-use is limited by covering damage rather than by the conductor, and the covering rarely survives a second stringing without new damage.

04Evaluation

How a covered lot is reviewed

Start with the covering and finish with the conductor, which is the reverse of bare conductor. Check for abrasion at tie points, for cracking along the top of the conductor where sun hit it, for rodent damage and for splits where the covering was gripped. A covering that is split is a place for water to enter, and the aluminum under it will already be pitted.

Then confirm what is underneath. The tag gives size and stranding; without it, cut back a few inches of covering at the end and measure a strand. This is the only material on the site where the cut-back is part of normal identification, because the covering hides everything a buyer would otherwise see.

Re-use is the hard question. Covered conductor that has been in service usually cannot go back up, because the covering that made it worth buying is the part that degraded. Expect a lot to be reviewed on conductor content, with any clean new surplus reels treated separately.

Safety before handling

A covered conductor is not a safe conductor. The covering will hold a branch off for a moment and will track and burn through under sustained contact, and the surface can carry leakage current that is not visible. Treat every covered conductor as bare, and require the circuit to be proved dead before anything is handled.

05Seller terms

Before you sell: how it works

Four things a seller should be able to pin down before a truck is booked.

01

Verification

Footage is checked against the reel tag, the sequential marks on the jacket, the wrap count against the barrel, or a published weight per 1,000 ft — whichever the reel actually supports.

02

Payment

Payment method and timing are agreed in writing for the specific lot before anything is loaded or moved. No verbal number is treated as an agreement.

03

Paperwork

A bill of sale for the lot, and for utility material the owning utility’s release reference. Neither is optional and neither is created after the fact.

04

Freight

Collection is arranged as part of the terms. Say what can lift the reels and whether a 53-foot trailer can reach them, and the pickup is planned around that.

No obligation

Sending a reel list and photographs costs nothing. A review is not a purchase, and nothing is bought, moved or scheduled until written lot terms are agreed for that material. Request a pickup when the lot is ready.

07Questions

Covered conductor questions

Is covered conductor re-usable after it has been taken down?

Sometimes, where the covering is undamaged and the conductor is dry. In practice the covering is abraded at the ties, so a removed lot is often reviewed on conductor content rather than on re-use.

How is tree wire different from 15 kV cable?

Cable has a semiconducting screen, a specified insulation wall and a metallic shield that grades the field. Covered conductor has a covering and nothing else, so it is a mechanical barrier rather than insulation.

Do you buy spacer cable with the spacers and messenger?

Yes, as a system lot. The messenger, spacers and ties are counted with the conductor, because a set is more useful than three separate lengths.

Can the covering be tested in the field?

A visual inspection at the ties and a cut-back at the end tell most of the story. Anything beyond that is a laboratory question and is not needed for a first review.

Send the covering type and a cut-back photograph

A few inches of stripped covering shows the conductor size and its condition. Reel count and footage finish the first pass.

Sell your wire

Send Us Your Reel List

A buyer reviews the lot and responds with questions or an offer basis.

No fee and no obligation. Prefer to talk? 614-715-3047 or saleselectricalbuyers@gmail.com

Call 614-715-3047Sell Your Wire