Surplus & obsolete wireUtility, plant and contractor lots

Station grounding · Georgia

We buy grounding grid conductor and bare copper

Ground grid conductor leaves a substation in one of two states: lifted clean during a rebuild, or cut out of a trench during demolition. The first is copper. The second is copper with soil, gravel and thirty years of corrosion attached, and it is reviewed accordingly.

  • Bare and tinned copper
  • Copper-clad steel
  • Ground rods
Reels stacked on end with coiled cable and a shrink-wrapped reel in a gravel yard
Reels stacked on end with coiled cable in a gravel yard.

Sell your wire

Tell us what you have

Six details are enough to start. Photos can follow by text or email.

No fee and no obligation. Prefer to talk? 614-715-3047 or saleselectricalbuyers@gmail.com

01Overview

What this page covers

A station ground grid is bare copper, most often 250 kcmil or 4/0, buried in a grid pattern with driven rods at the intersections and connections made exothermically or by compression. Older stations used copper-clad steel for the rods and sometimes for the conductor, and some used tinned copper where sulphide in the soil attacked plain copper.

The material is straightforward; the recovery is not. Grid conductor comes out in lengths, not on reels, and it comes out with connections attached, in soil, from an excavation that someone had to permit and dig. That shapes both the review and the practical difficulty of moving it.

02Specification

What the conductor and the site tell us

Sizes
2 AWG through 500 kcmil; 250 kcmil and 4/0 most common in grids
Materials
Soft-drawn bare copper, tinned copper, copper-clad steel
Stranding
Solid through 2 AWG; 7, 19, 37 and 61 strand above
Ground rods
Copper-clad steel, 5/8 in. by 8 ft and 10 ft, sectional rods
Connections
Exothermic welds, compression connectors, bolted clamps
Standards
ASTM B3 for soft copper wire, ASTM B8 for stranded copper
Condition
Lifted clean, excavated with soil attached, corroded, cut by theft
Documentation
Station drawing, ground grid plan, release from the owner

Tinned copper looks dull gray and is often mistaken for aluminum. A file or a scratch test settles it before the lot is described to anyone.

03Grounding material we buy

Grounding material we buy

01

Bare soft-drawn copper

The standard grid conductor, annealed and highly conductive. Soft temper matters: the conductor is meant to bend around trenches and rods, and a length that has been work-hardened by kinking is still copper but no longer grid material.

02

Tinned and coated copper

Tinned conductor from stations in sulphidic or coastal soil, and copper with a factory coating that has partly worn. The plating does not change the metal review, but it does change how the surface is described.

03

Copper-clad steel

Rods, and on older sites the conductor itself. Steel core, copper skin, and it is bought on copper content by a different route from plain copper. A magnet finds it immediately, which makes sorting simple.

04

Grid with connections attached

Exothermic welds and compression connectors come out with the conductor. They are cut off before the copper is weighed, and the count of intact connections tells a buyer how the grid was built and how it was removed.

04Evaluation

How a ground grid lot is reviewed

Size and material first, then the condition of the surface. Grid conductor has been in wet soil for decades, and the failure mode is a black, pitted surface and thinning at the point where it left the earth. Clean copper that has been lifted intact is a different lot from conductor that came out of a trench full of clay.

Quantity is the second question, and it is harder than it looks. Grid conductor is measured by length where it is intact and by weight where it is in pieces. A station ground grid plan gives a length to check against, which is a more reliable starting point than an eyeball estimate of a pile.

Release and excavation are the practical constraints. The grid belongs to the station owner, and lifting it is a digging job that usually belongs to the demolition contractor. State who is lifting it, whether the trench is open, and whether the conductor is above or below grade, because that decides whether a site visit is a walk-around or a machine job.

Safety before handling

Cutting a ground grid in a station that is still in service is a serious act. The grid is the path that keeps step and touch potential survivable, and removing a section changes the protection for everyone working near it. Grid recovery only proceeds once the owner has retired the station and confirmed that no live circuit or cathodic protection is connected.

05Seller terms

Before you sell: how it works

Four things a seller should be able to pin down before a truck is booked.

01

Verification

Footage is checked against the reel tag, the sequential marks on the jacket, the wrap count against the barrel, or a published weight per 1,000 ft — whichever the reel actually supports.

02

Payment

Payment method and timing are agreed in writing for the specific lot before anything is loaded or moved. No verbal number is treated as an agreement.

03

Paperwork

A bill of sale for the lot, and for utility material the owning utility’s release reference. Neither is optional and neither is created after the fact.

04

Freight

Collection is arranged as part of the terms. Say what can lift the reels and whether a 53-foot trailer can reach them, and the pickup is planned around that.

No obligation

Sending a reel list and photographs costs nothing. A review is not a purchase, and nothing is bought, moved or scheduled until written lot terms are agreed for that material. Request a pickup when the lot is ready.

07Questions

Grounding grid conductor questions

Is buried grid conductor worth recovering?

It depends on how much of it comes out intact. Copper that is corroded and broken into short pieces is reviewed on weight; clean lengths are reviewed as conductor.

How do you tell tinned copper from aluminum?

Scratch it. Tinned copper shows copper under a thin gray skin, weighs far more than aluminum for the same size, and does not ring when struck.

Do you buy copper-clad ground rods?

Yes, with the copper content reflected in the review. Rods are counted rather than weighed where they are straight and re-usable, and weighed where they are not.

Does the ground grid plan help?

Considerably. It gives a design length and a pattern, which is a check on the quantity and evidence of what was installed when the station was built.

Send the grid plan and the total length lifted

Whether the conductor is above grade, how much is intact and who is doing the lifting decide the review. Photographs of a cleaned section show the surface condition.

Sell your wire

Send Us Your Reel List

A buyer reviews the lot and responds with questions or an offer basis.

No fee and no obligation. Prefer to talk? 614-715-3047 or saleselectricalbuyers@gmail.com

Call 614-715-3047Sell Your Wire