Surplus & obsolete wireUtility, plant and contractor lots

Metal-clad cable · Georgia

We buy metal-clad cable for Georgia contractors

Interlocked armor over THHN or XHHW conductors, with a ground path built into the assembly. Leftover coils from a commercial fit-out are reviewed on armor condition, conductor size and how much of the coil is still on the reel.

  • 14 AWG to 1,000 kcmil
  • Aluminum or steel armor
  • HCF and standard
Reels of yellow, green and orange cable standing on end on gravel, with a substation lattice to the left and a steel building to the right
Mixed cable reels standing on end on gravel beside a steel building.

Sell your wire

Tell us what you have

Six details are enough to start. Photos can follow by text or email.

No fee and no obligation. Prefer to talk? 614-715-3047 or saleselectricalbuyers@gmail.com

01Overview

What this page covers

MC cable is a factory assembly: insulated conductors inside a formed metal armor, with either a bare ground conductor or an armor listed as an equipment ground. It is the default wiring method for commercial ceilings, parking structures, modular office walls and a great deal of light industrial work, and it is bought in 250, 500 and 1,000 ft coils that rarely get used to the last foot.

Leftover MC is one of the most common lots a commercial contractor holds, and one of the most often misdescribed. The armor type, the conductor count, the ground style and the temperature rating of the inner conductors all change what the coil is, and none of them can be read from a photograph of a coil sitting on a shelf.

02Specification

How an MC coil is identified

Construction
Interlocked armor over insulated conductors, 2 to 4 conductor
Armor
Aluminum or galvanized steel, interlocked; smooth or corrugated on some types
Conductors
THHN or THWN-2 singles, 14 AWG through 1,000 kcmil
Voltage
600 V; 2,000 V assemblies for industrial feeders
Ground
Bare conductor, or armor listed as the equipment ground
Types
MC, MC-IC, MC-PCS and HCF health care assemblies
Coils
250, 500 and 1,000 ft coils; larger on feeder sizes
Standards
UL 1569; armor and fitting listing shown on the tag

Photograph the cut end squarely. Conductor count, conductor colours, the presence of a bare ground and the armor profile all show in one frame at the end of a coil.

03What we review in this family

What we review in this family

01

Standard MC in aluminum armor

The lightest and most common commercial assembly, usually 12/2 and 12/3 for branch circuits and 10 AWG for small equipment. Aluminum armor dents rather than kinks, and a dent that has closed on the conductors is the main defect worth looking for.

02

Steel-armored MC for industrial work

Galvanized steel interlock in the same conductor configurations, chosen where abrasion and physical damage are expected. Reviewed on rust at the cut ends and along the spiral, since a coil stored on a damp floor rusts from the outside in.

03

HCF health care assemblies

MC with a redundant ground path, built for patient care areas where an equipment ground must not depend on a single path. The extra conductor is visible at the cut end and is the quickest way to tell an HCF coil from a standard one.

04

Feeder MC and 2 kV assemblies

Large-conductor MC from 1/0 up, used for risers and equipment feeds. Supplied on heavier coils or returnable reels and reviewed on footage first, because the conductor value sits in the length rather than the armor.

04Evaluation

How a leftover MC coil is reviewed

Start at the cut end. The armor profile, the conductor count, the colours, the presence or absence of a bare ground and the printed legend on the inner conductors are all in that one view. A coil with the end taped and the conductors trimmed back short is harder to read than one that was cut cleanly and left alone.

Armor condition decides more than sellers expect. A coil that has been dragged across a slab has flats and crushed spirals; a coil stored against a wall has rust along one side only. Neither prevents the cable from being used, but both change the review, and both are visible before the coil is unrolled.

Then footage. Part coils of MC are usually measured rather than trusted, either by the tag on the coil, the counter on the machine that cut it, or a physical pull. Say how many coils and whether they are banded, because a coil that has lost its ties arrives as a spring and is reviewed accordingly.

Safety before handling

Cut armor is sharp on both edges and the interlock holds a memory of the coil. Gloves and eye protection are not optional when a banded coil is released, and a coil should never be cut open with the conductors still connected at the far end.

05Seller terms

Before you sell: how it works

Four things a seller should be able to pin down before a truck is booked.

01

Verification

Footage is checked against the reel tag, the sequential marks on the jacket, the wrap count against the barrel, or a published weight per 1,000 ft — whichever the reel actually supports.

02

Payment

Payment method and timing are agreed in writing for the specific lot before anything is loaded or moved. No verbal number is treated as an agreement.

03

Paperwork

A bill of sale for the lot, and for utility material the owning utility’s release reference. Neither is optional and neither is created after the fact.

04

Freight

Collection is arranged as part of the terms. Say what can lift the reels and whether a 53-foot trailer can reach them, and the pickup is planned around that.

No obligation

Sending a reel list and photographs costs nothing. A review is not a purchase, and nothing is bought, moved or scheduled until written lot terms are agreed for that material. Request a pickup when the lot is ready.

07Questions

MC cable questions

Does MC cable need a separate ground wire?

Not always. Many MC assemblies use a listed interlocked armor as the equipment ground and carry no green conductor. HCF and some spec-driven assemblies add a redundant ground, which is visible at the cut end.

Do you buy part coils with a few feet left?

Yes, as part coils. Short remnants are grouped and reviewed together. A coil under ten feet is generally treated as cut scrap rather than as cable.

Can MC with crushed armor still be used?

Sometimes, but it has to be inspected along the crushed section for conductor damage, and the damaged length is normally cut out. Say where the damage is rather than describing the coil as good.

Is aluminum armor worth less than steel?

It is reviewed differently rather than ranked. Aluminum armor is lighter and more common on commercial work; steel is chosen for abuse. Condition of the armor matters more than which metal it is.

Photograph the cut end first

One square photograph of the cut end, one of the coil banded and one of the tag will answer most of the questions. Coil count and approximate remaining length finish it.

Sell your wire

Send Us Your Reel List

A buyer reviews the lot and responds with questions or an offer basis.

No fee and no obligation. Prefer to talk? 614-715-3047 or saleselectricalbuyers@gmail.com

Call 614-715-3047Sell Your Wire